Roofing & exterior

Roof Pitch Calculator

Calculate rise per 12 inches of horizontal run, slope percentage and angle from measured rise and run.

Created and Written by: Designation: Founder

Technically reviewed by: Riya Kulkarni | BE Civil Engineer

Enter rise and horizontal run

Unit changes convert your dimensions. Rise and run may use different units; the calculation converts them before division.

Measured roof segment

Use the vertical rise and level horizontal distance between the same two points. Run is not the sloping roof length. Do not use the full building span as one side’s run; half-span applies only to an appropriate symmetric roof geometry.

The starting 6-inch rise over 12-inch run is an editable example. Zero rise is allowed; zero run is undefined. Enter upward rise as a nonnegative magnitude.

Horizontal runRiseRoof surface
Measurement guide · not to scale.
EXAMPLE ESTIMATE
6:12

Rise per 12 inches of horizontal run

Slope percentage
50%
Angle above horizontal
26.565°
Rise / run
0.5
Vertical rise
0.5 ft
Horizontal run
1 ft
Metric rise
0.152 m
Metric run
0.305 m

Calculation basis

Rise/run = 0.5. Pitch per 12 = ratio × 12. Percent slope = ratio × 100. Angle = arctangent(ratio), converted to degrees.

Uses the common rise-per-12 convention. Traditional rise/full-span pitch is a different ratio. Display rounds to 3 decimals; calculations use unrounded inputs. Geometry only: confirm roofing product, drainage, structural and local requirements separately.

Formula and worked example

Convert rise and horizontal run into the same length unit. Slope ratio = vertical rise ÷ horizontal run. Rise per 12 = 12 × slope ratio. Slope percentage = 100 × slope ratio. Angle above horizontal = arctangent(slope ratio), converted from radians to degrees by multiplying by 180/π.

Example: 6 inches of vertical rise over 12 inches of horizontal run gives a ratio of 0.5. The result is 6:12, a 50% slope and an angle of 26.565051177 degrees. These describe the same geometry; 50% is not 50 degrees.

What run means

Run is the level horizontal distance between the same two points used for rise. It is not the sloping roof-surface length. A full building span is not automatically the run of one roof plane. Half-span applies only where the actual roof geometry supports it, such as an appropriate symmetric arrangement. For irregular roofs, use measurements belonging to the particular segment being assessed.

Pitch convention

This calculator uses the common roof slope convention of rise per 12 units of horizontal run, often called roof pitch. The same ratio applies in any matching length unit: 6 inches per 12 inches is equivalent to 6 feet per 12 feet. Traditional pitch expressed as rise divided by full span is a different quantity. Confirm the convention used on your drawings.

Independent examples

300 mm rise over 600 mm horizontal run also gives 6:12, 50% and 26.565051177°. A 3 ft rise over 4 ft run gives 9:12, 75% and 36.869897646°. Equal rise and run gives 12:12, 100% and 45°. Zero rise with positive run gives 0:12, 0% and 0°.

Units, validation and rounding

Rise and run may have different units; conversion happens before division. Unit selectors and the inches/millimeters buttons convert your entered dimensions. Inputs accept finite decimals of up to 40 characters. Rise must be nonnegative; horizontal run must be positive. Positive dimensions support 0.000001–1,000,000 ft, and rise/run ratios above 1,000 are rejected as an input sanity limit. This range is not a recommended roof slope.

Displayed results use up to three decimals while calculations use unrounded inputs. The measurement diagram is illustrative and not to scale. A result such as 6:12 means 6 inches of rise per 12 inches of horizontal run, not a 6-degree angle.

Scope of this calculation

This is geometry only. It does not select roofing materials, establish minimum allowable slope, assess drainage, size rafters, determine structural capacity, calculate roof area or approve a code-compliant assembly. A level geometric result does not demonstrate adequate roof drainage. Confirm actual product instructions, project requirements and roof geometry separately. Dedicated roofing, roof area, rafter and pitch/angle conversion pages remain separate calculators in the development queue.

Reference

GAF: Understanding Roof Slope defines roof slope using vertical rise and horizontal run, including the rise-per-12 convention. This calculator uses that geometric convention without determining whether a roof covering is suitable.

Related calculators

All calculators

TECHNICAL REVIEWER

Riya Kulkarni | BE Civil Engineer

Riya Kulkarni qualifications and experience
QualificationBE Civil – Shivaji University, Kolhapur (2018)
Experience8+ Years
Technical SpecialisationsStructural Engineering, Construction Materials, Site Execution and Concrete Technology.

Project experience

1. Shree Ganesh Residency

Location: Rajarampuri, Kolhapur

Project Type: G+4 Residential Apartment Building

Technical responsibilities
  • RCC structural construction coordination.
  • Reinforcement and shuttering inspection.
  • Concrete pouring and curing supervision.
  • Monitoring construction materials and workmanship.
  • Site quality-control documentation.

2. Vrindavan Heights

Location: Tarabai Park, Kolhapur

Project Type: G+5 Residential Building

Technical responsibilities
  • Structural drawing interpretation.
  • Reinforcement detailing checks.
  • Concrete workability and placement monitoring.
  • Construction sequencing and site coordination.
  • Building material quality assessment.

3. Sai Krupa Row Houses

Location: Kalamba Road, Kolhapur

Project Type: Residential Row Housing Development

Technical responsibilities
  • Foundation and plinth construction coordination.
  • Brick masonry and plastering inspection.
  • Concrete mixing, placement and curing.
  • Waterproofing and finishing work coordination.
  • Construction progress documentation.

4. Greenview Enclave

Location: Ujalaiwadi, Kolhapur

Project Type: G+3 Residential Apartment Complex

Technical responsibilities
  • Site execution monitoring.
  • RCC work and reinforcement inspection.
  • Construction material management.
  • Concrete quality testing coordination.
  • Workmanship and quality documentation.

5. Lotus Business Plaza

Location: Shahupuri, Kolhapur

Project Type: G+3 Commercial Building

Technical responsibilities
  • Structural construction coordination.
  • Slab and column reinforcement inspection.
  • Concrete placement and quality monitoring.
  • Construction activity sequencing.
  • Contractor and site-team coordination.

6. Omkar Residency

Location: Kadamwadi, Kolhapur

Project Type: G+5 Residential Apartment Building

Technical responsibilities
  • Foundation and superstructure execution coordination.
  • Reinforcement and formwork inspection.
  • Concrete testing and curing monitoring.
  • Material specifications and quality checks.
  • Site inspection reporting.

7. Silver Oak Villas

Location: Kasaba Bawada, Kolhapur

Project Type: Independent Residential Villa Development

Technical responsibilities
  • Residential foundation construction.
  • RCC structural component inspection.
  • Masonry and plastering quality checks.
  • Flooring and finishing coordination.
  • Site execution and material monitoring.

8. Pratham Commercial Complex

Location: Ruikar Colony, Kolhapur

Project Type: Commercial and Retail Building

Technical responsibilities
  • RCC construction coordination.
  • Concrete quality-control procedures.
  • Structural component inspection.
  • Construction material assessment.
  • Execution progress and quality reporting.