Formula and worked example
Let D be actual outside diameter and t be uniform radial wall thickness. Inside diameter d = D − 2t. Steel cross-sectional area A = π(D² − d²) ÷ 4 = πt(D − t). Mass per length = A × steel mass density. Mass per pipe = A × length × density. Total mass = mass per pipe × identical pipe count.
The factored area formula πt(D − t) is used so thin walls do not require subtracting almost equal squared diameters. Area is steel material only; the hollow bore contributes no steel mass. All dimensions are converted into consistent units before multiplication.
Default arithmetic example: D = 2.375 in and t = 0.154 in give d = 2.067 in and steel area 0.342034π = approximately 1.074531501678 in². One 10 ft length contains approximately 0.002113009979 m³ of steel. At the editable 7850 kg/m³ density, one pipe has theoretical mass 16.5871283317 kg or 36.5683583516 lb. Two pipes total 33.1742566634 kg or 73.1367167032 lb. Starting dimensions are arithmetic inputs, not a selected or approved pipe schedule.
Actual outside diameter is not a nominal size
Enter the full outside diameter, not radius, inside diameter, NPS or DN. Nominal designations identify pipe sizes; they are not measurements to substitute into this geometry formula. Obtain outside diameter and wall thickness from verified product data, approved schedules or suitable measurements. This page provides no automatic nominal-size or schedule lookup.
Wall thickness is radial and occurs on both sides of a diameter. Twice the wall must be strictly less than outside diameter so the bore stays positive. A solid bar needs the separate Steel Weight or focused rod calculation. Straight circular concentric uniform walls are assumed; oval, eccentric, tapered or irregularly corroded sections need a different takeoff.
Independent metric reference
For D = 100 mm and t = 5 mm, inside diameter is 90 mm. Steel area = π(100² − 90²) ÷ 4 = 475π mm², approximately 1492.256510455 mm². At 7850 kg/m³, mass per metre = 3.72875π, approximately 11.7142136071 kg/m. Each 6 m length has 70.2852816424 kg; two lengths total 140.5705632849 kg.
Equivalent metric inputs 60.325 mm outside diameter, 3.9116 mm wall and 3.048 m length reproduce the default US dimensions. If a separately entered density is 490 lb/ft³, two default 10 ft pipes total approximately 73.1278383086 lb. That differs from the 7850 kg/m³ example because these rounded density assumptions are not exact equivalents.
Density and units
The editable 7850 kg/m³ starting assumption is approximate, not a grade choice or product guarantee. Verify the actual alloy and product density. Density accepts kg/m³ or lb/ft³. Its selector retains the source number, so enter the matching value after selecting units. Length selectors convert valid entries to 12 significant digits; verify conversions before calculating.
Length units are ft, in, yd, m, cm and mm, independently selectable for diameter, wall and pipe length. One foot equals 0.3048 m exactly and one pound equals 0.45359237 kg exactly. Results distinguish US short tons (2000 lb) from metric tonnes (1000 kg). Weight means mass on this page, not force.
Steel-only estimate and actual delivered mass
The result excludes contents, water, fluid, linings, coatings, flanges, valves, fittings, couplings, added weld metal, attachments and packaging. It does not add cutting waste, spare lengths, stock-length rounding or supplier order increments. Count only identical lengths of this section; estimate other lengths or sizes separately.
Real pipe dimensions, wall tolerances, ovality, weld details, end preparation and product treatments may produce differences from the theoretical geometric estimate or a rounded nominal table. Use verified supplier unit weights or measured delivered masses when those are required. No universal tolerance or correction factor is silently applied. This page does not determine minimum required wall, remaining corrosion allowance, pressure rating, buckling, structural capacity or safe lifting and transportation arrangements.
Precision and input checks
Reduced decimal fractions preserve the entered values through unit conversion and geometry; π is approximated to 40 decimal places. Final output rounds to three decimals, with scientific notation for very small positive results. Display rounding does not change the underlying mass calculation. Use original dimensions and unrounded project data when precision matters.
Positive diameter, wall and length must be between 0.000001 and 1000000 ft after conversion; steel area must be between 0.000000000001 and 100 m². Pipe count must be a whole number from 1 to 1000000. Combined length is limited to 1 billion ft and total mass to 1 billion kg. Density is limited to 1000–20000 kg/m³ after conversion as an entry check, not an approved material range. Decimal inputs accept up to 18 places. Geometrically invalid walls are rejected before a result is shown.
References
Atlas Steels: Carbon steel pipe dimensions and weights describes its weights as approximate theoretical values and provides a rounded metric pipe-mass formula. This historical document is cited for the geometric estimating method, not as a current pipe specification or schedule selection. Civilable uses the full annulus formula and entered density rather than a fixed rounded coefficient.
SSAB: 20 questions about steel provides an approximate steel density reference. Verify actual product data; this starting assumption is not universal. Use Steel Weight for other section shapes and Rebar Weight for nominal US reinforcing-bar table weights.